CAL-400 mV mA Calibrator
₹12,150.00 including GST @18%
NEW LAUNCH!!
mV mA Calibrator for Measuring and Source of 100mV / 30V DC Voltage, 20mA DC Current and switching value measurements. Supports manual Step Output, Automatic Waveform Output, and allows for simultaneous display of Voltage (V), Current (mA), and percentage. Loop detection function, overload protection.
- Description
- Additional information
- SPECIFICATIONS
- CATALOGUE
- Reviews (0)
Description
NEW LAUNCH!!
The Metravi CAL-400 mV/mA Calibrator is versatile and precise, designed to meet the needs of professionals in testing, calibration, and troubleshooting applications.
With its wide range of functions, this device offers 100mV / 30V DC Voltage measurement, 20mA DC Current measurement, and switching value measurement, ensuring high accuracy and reliability.
In addition to measurement capabilities, the Metravi CAL-400 provides 100mV / 30V DC Voltage Output, 20mA DC Current output, and SIMULATE output, making it a powerful tool for calibration tasks.
It supports manual Step Output, Automatic Waveform Output, and allows for simultaneous display of Voltage (V), Current (mA), and percentage, offering enhanced usability and efficiency.
Equipped with a loop detection function, the calibrator can simultaneously provide a 24V Loop Power supply while measuring Current, making it ideal for loop testing in process control applications.
With built-in overload protection, the Metravi CAL-400 ensures safety and durability, making it a must-have tool for professionals in industries such as instrumentation, automation, and maintenance.
Additional information
| Brand | |
|---|---|
| Colour | |
| Model | |
| Warranty |
- Sampling Time: 2-3 times / second
- Overload Protection: 50mA/30V
- Overrange Display: OL
- Power Source: 3 x 1.5V ( LR03/AAA ) Alkaline Batteries
- Low Battery Indication: Shows battery sign
- Auto Shutdown: After 15 min of non-operation
- Warm-up Time: 10 mins
- Calibration Cycle: One year
MEASURE
- DC Voltage Range:
- 100mV: -10.0mV~110.0mV, Resolution 100uV
- 30V: -5.00V~30.00V, Resolution 10mV
- Accuracy: 0.2%+4
- DC Current Range: 20mA: 0.00mA~22.00mA, Resolution 0.01mA
- Accuracy: 0.2%+4
SOURCE
- DC Voltage Range:
- 100mV: 0.0mV~110.0mV, Resolution 100uV
- 10V: 0.00V~11.00V, Resolution 10mV
- Accuracy: 0.2%+4
- DC Current Range: 20mA: 0.00mA~22.00mA, Resolution 0.01mA
- Accuracy: 0.2%+4
- Analogue Transmitter SIMULATE: -20mA: 0.00mA~22.00mA, Resolution 0.01mA
- Accuracy: 0.2%+4
- Loop Power Supply: 24V
- Accuracy: ±10%
- Capacitive Load: ≥ 0.01μF
View Catalogue: Metravi CAL-400 mV mA Calibrator Catalogue
Be the first to review “CAL-400 mV mA Calibrator”
You must be logged in to post a review.













































Reviews