CAL-400T Universal Calibrator

13,365.00 including GST @18%

NEW LAUNCH!!
Measurement and Source for 100mV / 30V DC Voltage, 20mA DC Current and switching value measurements. Supports manual Step Output, Automatic Waveform Output, and allows for simultaneous display of Voltage (V), Current (mA), and percentage. Loop detection function, overload protection. Supports 8 thermocouple types (R, S, B, K, E, J, T, and N) for both measurement and output, Temperature in °C/°F.  Automatic and manual cold junction compensation.

Compare

Description

NEW LAUNCH!!
The Metravi CAL-400T is a high-precision Universal Calibrator, designed for professionals who require versatile and reliable calibration for electrical and temperature measurements.
This advanced device supports 100mV/30V DC Voltage measurement, 20mA DC Current measurement, and switching value measurement, ensuring accurate diagnostics and troubleshooting.

Beyond measurement, the Metravi CAL-400T offers 100mV/30V DC Voltage Output, 20mA DC Current output, and SIMULATE output, making it ideal for testing and calibration applications.
It features manual step and automatic waveform output, with a simultaneous display of Voltage (V), Current (mA), and percentage for enhanced convenience.
Equipped with a loop detection function, this calibrator provides a 24 V loop power supply while measuring current, essential for process control and industrial automation.

Additionally, it supports eight thermocouple types (R, S, B, K, E, J, T, and N) for both measurement and output, along with temperature display in Celsius and Fahrenheit. With automatic and manual cold junction compensation, it ensures precise temperature calibration.

Built for safety and durability, the Metravi CAL-400T includes overload protection, making it a robust and indispensable tool for instrumentation engineers, process control specialists, and maintenance professionals.

Additional information

Brand

Colour

Model

Warranty

  • Sampling Time: 2-3 times per second
  • Overload Protection: 50mA/30V
  • Overrange Display: OL
  • Power Source: 3 x 1.5V (LR03/AAA) Alkaline Batteries
  • Low Battery Indication: Shows battery sign
  • Auto Shutdown: After 15 minutes of non-operation
  • Warm-up Time: 10 minutes
  • Calibration Cycle: One year

MEASURE

  • DC Voltage Range:
    • 100mV: -10.0mV~110.0mV, Resolution 100uV
    • 30V: -5.00V~30.00V, Resolution 10mV
  • Accuracy: 0.2%+4
  • DC Current Range: 20mA: 0.00mA~22.00mA, Resolution 0.01mA
  • Accuracy: 0.2%+4
  • Temperature / Thermocouple Ranges:
    • Type R: 0° ~ 1760°C
    • Type S: 0° ~ 1760°C
    • Type B: 400° ~ 1820°C
    • Type K: -200° ~ 1370°C
    • Type E: -200° ~ 1000°C
    • Type J:  -200° ~ 1200°C
    • Type T: -200° ~ 400°C
    • Type N: -200° ~ 1300°C
  • Resolution: 1°C
  • Accuracy: 0.2% + 4

SOURCE

  • DC Voltage Range:
    • 100mV: 0.0mV~110.0mV, Resolution 100uV
    • 10V: 0.00V~11.00V, Resolution 10mV
  • Accuracy: 0.2%+4
  • DC Current Range: 20mA: 0.00mA~22.00mA, Resolution 0.01mA
  • Accuracy: 0.2%+4
  • Analogue Transmitter SIMULATE: -20mA: 0.00mA~22.00mA, Resolution 0.01mA
  • Accuracy: 0.2%+4
  • Loop Power Supply: 24V
  • Accuracy: ±10%
  • Temperature / Thermocouple Ranges:
    • Type R: 0° ~ 1760°C
    • Type S: 0° ~ 1760°C
    • Type B: 400° ~ 1800°C
    • Type K: -200° ~ 1350°C
    • Type E: -200° ~ 700°C
    • Type J:  -200° ~ 950°C
    • Type T: -200° ~ 400°C
    • Type N: -200° ~ 1300°C
  • Resolution: 1°C
  • Accuracy: 0.2% + 4
  • Capacitive Load: ≥ 0.01μF